Hold-up time (bridging time)
Hold-up time is a bridging time that describes the period during which the specified output power continues to be provided in the event of an input voltage failure. Even normal power supply units can bridge short-term power failures of up to a few seconds using appropriately dimensioned input storage electrolytic capacitors. The bridging time is more than 21 ms and the power OK signal is accurate.
Inrush current (starting current or inrush current)
All power supplies generate a so-called inrush current, which often far exceeds their nominal current consumption. The causes are the charging of the different capacitances in the input circuit and in the EMC filters, the build-up of the magnetic field in the transformer core and even the charging of the capacitors in the output filter. This input current only drops back to normal values when the converter is operating stably. The inrush currents are low.
Timings
The power supply supports alternative low-power modes.
- 1 - Introduction and technical data
- 2 - Unboxing, cables and protection circuits
- 3 - Teardown: Topology and components
- 4 - Load Regulation, Ripple Suppression
- 5 - Transient Response
- 6 - Hold-Up Time, Timings, Inrush-Current
- 7 - Average Efficiency and PF
- 8 - Noise and fan control
- 9 - Summary and conclusion