Transient response (transient behavior)
The transient response is mediocre overall. Helly should improve the terrible response of the 3.3V rail.
20% Load – 20ms
Voltage | Before | After | Change | Pass/Fail |
12V | 12.023V | 11.968V | 0.46% | Pass |
5V | 5.068V | 5.008V | 1.19% | Pass |
3.3V | 3.321V | 3.221V | 3.03% | Pass |
5VSB | 5.056V | 5.010V | 0.91% | Pass |
50% Load -20ms
Voltage | Before | After | Change | Pass/Fail |
12V | 11.998V | 11.944V | 0.45% | Pass |
5V | 5.061V | 4.998V | 1.24% | Pass |
3.3V | 3.311V | 3.206V | 3.17% | Pass |
5VSB | 5.041V | 4.993V | 0.95% | Pass |
Transient Response ATX v3.1 Tests
The power supply passes all ATX v3.1 transient response tests, but the 3.3 V rail drops at the limit in the 200% load test.
The 12 V rail performs well, but not as well as in the normal transient response tests.